Filament length allways 0 #42

@PitHerm

Description

@PitHerm

Filament length is always reported as 0

Solution:
FILE OctoPrintAPI.h :
CHANGE:
long jobFilamentTool0Length;
TO:
float jobFilamentTool0Length;
AND
CHANGE:
long jobFilamentTool1Length;
TO:
float jobFilamentTool1Length;

FILE OctoPrintAPI.cpp:
CHANGE:
printJob.jobFilamentTool0Length = root["job"]["filament"]["tool0"]["length"] | 0;
TO:
printJob.jobFilamentTool0Length = root["job"]["filament"]["tool0"]["length"] | 0.0;
AND
CHANGE:
printJob.jobFilamentTool0Length = root["job"]["filament"]["tool1"]["length"] | 0;
TO:
printJob.jobFilamentTool0Length = root["job"]["filament"]["tool1"]["length"] | 0.0;