Notifications
You must be signed in to change notification settings - Fork 51
Open
Description
For simple analytical test cases, it is useful to prescribe the transfer coefficients cdd, cde, cdh.
In order to handle this, would it be possible to add a third option in addition to "kondo" and "fairall" which could be "constant_cd" with 3 variables: cdd, chd, ced?
this could be done either independently: airsea_fluxes could look like
select case (method)
case (1) ! Kondo
call kondo(sst,airt,u10,v10,precip,evap,taux,tauy,qe,qh)
case (2) ! Fairall et. all
call fairall(sst,airt,u10,v10,precip,evap,taux,tauy,qe,qh)
case default
call constant_cd(sst,airt,u10,v10,precip,evap,taux,tauy,qe,qh)
end select
with an additional subroutine constant_cd
or within kondo and fairall: This can be easily done for instance at the end of these routines:
if (constant_cd) then
cdd = ... input value ...
chd = ...
ced = ...
end if
I am happy to propose a pull request for option 1 or 2
Metadata
Metadata
Assignees
Labels
No labels