Notifications
You must be signed in to change notification settings - Fork 52
Open
Description
I am writing a client which needs to recover from temporary inability to connect to the modbus server the bare bones of what I'm trying to do is as follows
// Variables into which the data read from the MODBUS is put, available for forwarding to any web consumer
var meterVolts
const U16_METER_V = 33128 //Register Volts at meter in tenths of a Volt
//****************************************************************
//
// MODBUS Handler etc (functions followed by some inline code)
//
//****************************************************************
const modbus = require("modbus-stream");
const util = require('util')
function getValuesPromise(connection,req){
return new Promise ((resolve, reject) => {
if (connection == null)
reject('Connection found to be closed')
connection.readInputRegisters(req,(err,res) => {
if (err)
reject(err)
else
resolve(res.response.data)
})
})
}
async function getInverterInfo(connection){
connection.transport.on("error", function (err){
console.log("transport error",err)
//raise reconnect request event
return
})
connection.transport.on("close", function(err){
console.log("transport close",err )
return
})
//Meter voltage as a way to test manipulation of a U16 result
meterVolts = await getValuesPromise(connection,{address:U16_METER_V, quantity: 1, extra: { unitId: 1}}).catch(err => {console.log(err)})
setTimeout(() => {getInverterInfo(connection)},10000) //Run again after ten seconds
}
modbus.tcp.connect(8899,"192.168.100.242",{debug: null}, (err, connection)=> {
if (err != null){
console.log('could not connect')
console.log(err)
};
getInverterInfo(connection) //This kicks a repeat timer.
});
`
However, I'm finding that if I reset the server during the 'wait' time, instead of cleanly catching either a "close" or an "error" event, I see the following in my console:
Error: GatewayTargetDeviceFailedToRespond
at exports.error (/home/solar/node_modules/modbus-pdu/lib/Exception.js:24:13)
at Timeout._onTimeout (/home/solar/node_modules/modbus-stream/lib/transport/transport.js:93:33)
at listOnTimeout (node:internal/timers:564:17)
at process.processTimers (node:internal/timers:507:7) {
code: 11
}
Can anyone help me understand what I'm doing wrong?
Metadata
Metadata
Assignees
Labels
No labels