Skip to content

How to catch tcp transport errors #74

@boatbodger

Description

@boatbodger

I am writing a client which needs to recover from temporary inability to connect to the modbus server the bare bones of what I'm trying to do is as follows

// Variables into which the data read from the MODBUS is put, available for forwarding to any web consumer
var meterVolts
const U16_METER_V = 33128		//Register Volts at meter in tenths of a Volt
//****************************************************************
//
//       MODBUS Handler etc (functions followed by some inline code)
//
//****************************************************************

const modbus = require("modbus-stream");
const util = require('util')

function getValuesPromise(connection,req){
	return new Promise ((resolve, reject) => {
		if (connection == null)
			reject('Connection found to be closed')
		connection.readInputRegisters(req,(err,res) => {
			if (err)
				reject(err)
			else 
				resolve(res.response.data)
		})
	})
}

async function getInverterInfo(connection){

	connection.transport.on("error", function (err){
			console.log("transport error",err)
			//raise reconnect request event
			return
	})
	connection.transport.on("close", function(err){
		console.log("transport close",err )
		return
	})

	//Meter voltage as a way to test manipulation of a U16 result
	meterVolts =  await getValuesPromise(connection,{address:U16_METER_V, quantity: 1, extra: { unitId: 1}}).catch(err => {console.log(err)})

	setTimeout(() => {getInverterInfo(connection)},10000)	//Run again after ten seconds
}


	modbus.tcp.connect(8899,"192.168.100.242",{debug: null}, (err, connection)=> {
		if (err != null){
			console.log('could not connect')
			console.log(err)
		};

		getInverterInfo(connection)	//This kicks a repeat timer.

	});
`

However, I'm finding that if I reset the server during the 'wait' time, instead of cleanly catching either a "close" or an "error" event, I see the following in my console:

Error: GatewayTargetDeviceFailedToRespond
    at exports.error (/home/solar/node_modules/modbus-pdu/lib/Exception.js:24:13)
    at Timeout._onTimeout (/home/solar/node_modules/modbus-stream/lib/transport/transport.js:93:33)
    at listOnTimeout (node:internal/timers:564:17)
    at process.processTimers (node:internal/timers:507:7) {
  code: 11
}

Can anyone help me understand what I'm doing wrong?