Skip to content

Conversation

@coldtobi
Copy link

@coldtobi coldtobi commented Dec 22, 2018

We observerd a strange error yielding in dead tips* we attribute
to shorts between two contacts on the 3.5 mm connector** (bad cable...)
and we hope this failure mode will be covered by this feature.

The feature works by monitoring the temperature and making sure that
in a certain time a certain temperature rising is seen.

The tuning can be done by a few parameters:

  • WATCH_TEMP_PERIOD -- The time the temperature has to rise
  • WATCH_TEMP_INCREASE -- by this value
  • WATCH_TEMP_DEACTIVATE -- if we are that close to the target temperature, disable
    this protection.
  • WATCH_TEMP_REBOUND -- if the temperature drops below the target
    window (e.g by cleaning with a wet sponge), wait this time until
    the protection is re-armed.

* heating up at full power, until red-glowing and then dying)

** it might be short between tip and ring1, combined with phase reversal on the OpAmp
caused by exceeding the OpAmps Common Mode voltage ratings.. But this is
only a theory...

Tobias Frost and others added 19 commits December 21, 2018 10:26
Define "FAST_BOOT" and the boot screen will be only shown briefly.
To enter the options menu, you can press the button already when you
turn on the Maiskolben (or while the Maiskolben splash screen is
showing.)
components, regardless of the scaling of the LCD.
(Bikeshedding, I know, but I find it confusing when the soldering iron
is off and press short on that it enters standby mode, but without
heating it to standby temperature)
(the biggest I have in my stock, and therefore the slowest to heat)
…(incomplete for the parts my hardware does not support)
I've replaced the output transitor with a ProFET, Infineon BTS420.
This guy needs an higher integral part for the PID, or it is 4-5°C off.
…ernal power to USB it takes quite long to recognize.)x
Print a battery symbol, dependent on charge level.
Print it cyan when charging, print it green when fully charged.
On Battery, print it colored from red to green, depending on charge
level.

Untested: If no battery is present, print the power chord symbol only
(cannot test because my hardware is a bit f***ed up.)
Weller tips are rated for 40W (at least most of them). On higher input
voltage, this is exceeded.
This feature limits it by put a cap on the pwm, dependent on the input
voltage.
We observerd a strange error yielding in dead tips* we attribute
to shorts between two contacts on the 3.5 mm connector** (bad cable...)
and we hope this failure mode will be covered by this feature.

The feature works by monitoring the temperature and making sure that
in a certain time a certain temperature rising is seen.

The tuning can be done by a few parameters:
  - WATCH_TEMP_PERIOD -- The time the temperature has to rise
  - WATCH_TEMP_INCREASE -- by this value
  - WATCH_TEMP_DEACTIVATE -- if we are that close to the target temperature, disable
        this protection.
  - WATCH_TEMP_REBOUND -- if the temperature drops below the target
        window (e.g by cleaning with a wet sponge), wait this time until
        the protection is re-armed.

* heating up at full power, until red-glowing and then dying)

** it might be tip and ring1, combined with phase reversal on the OpAmp
caused by exceeding the OpAmps Common Mode voltage ratings.. But this is
only a theory...
Tobias Frost and others added 4 commits November 19, 2025 07:50
The rebound timer was never re-activated and not initialized with the
correct value.
fixing some corner-cases, making it more reliable and less often to drop out due to false positivss.
make the rebound time a bit longer as well.