117 changes: 115 additions & 2 deletions cif_pow.dic
Original file line number Diff line number Diff line change
Expand Up @@ -6484,6 +6484,118 @@ save_PD_INSTR
_name.object_id PD_INSTR
_category_key.name '_pd_instr.id'

loop_
_description_example.case
_description_example.detail
;
_diffrn_radiation.id Hires_tube

loop_
_diffrn_radiation_wavelength.id
_diffrn_radiation_wavelength.type
_diffrn_radiation_wavelength.value
1 'Cu K\a~1~' 1.540596

_pd_instr.id b4131be5
_pd_instr.geometry
;
Bragg-Brentano, pre-specimen double-bounce monochromator.
Dual strip detectors covering ~20° each. Scanned to cover all angles.
;
_pd_instr.2theta_monochr_pre 45.31
_pd_instr.monochr_pre_spec 'Ge 220'
_pd_instr.divg_eq_mono_spec 0.2
_pd_instr.cons_illum_flag no
_pd_instr.detector_circle_radius 320
_pd_instr.dist_mono_spec 402
_pd_instr.dist_src_mono 39
_pd_instr.beam_size_ax 10.5
_pd_instr.slit_ax_mono_spec 10.0
_pd_instr.slit_eq_mono_spec 0.5
_pd_instr.soller_ax_mono_spec 2.5
_pd_instr.source_size_ax 12
_pd_instr.source_size_eq 0.4
_pd_instr.location 'Physics, Anytown University.'
;
;
This instrument is identified by the id b4131be5. The instrument is
described as a Bragg-Brentano diffractometer with a pre-specimen,
double-bounce Ge 220 monochromator. It has two detectors; these are not
described here, see PD_INSTR_DETECTOR. The monochromator is set at
45.31° 2θ. The equatorial divergence between the monochromator and
specimen is fixed at 0.2°; this instrument is not run in constant
illumination length mode.

The distance from the virtual source to the specimen for all
measurement points is 320 mm, whereas the distance from the
monochromator to the specimen is 402 mm. The monochromator is
situated 39 mm from the source. The width of the beam on the specimen,
in the axial direction, is 10.5 mm, and the width of the beam is
defined at the monochromator by a 10 mm mask. There is a 0.5 mm
equatorial slit between the monochromator and specimen, which can be
assumed to be on the detector circle, and acts as the virtual source.

There are 2.5° axial Soller slits between the monochromator and the
specimen. The size of the source in the X-ray tube is 12 x 0.4 mm.

The instrument is located in the Department of Physics in Anytown
University.

The radiation used in the instrument is defined by data names from the
DIFFRN_RADIATION_WAVELENGTH category. In this case, it is pure Cu K\a~1~
radiation with a wavelength of 1.540596 Å.
;
;
_diffrn_radiation.id Cobalt_tube
loop_
_diffrn_radiation_wavelength.id
_diffrn_radiation_wavelength.value
_diffrn_radiation_wavelength.wt
_diffrn_radiation_wavelength.type
_diffrn_radiation_wavelength.details
1 1.7889847 0.378 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
2 1.7892524 0.144 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
3 1.7896946 0.127 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
4 1.7888515 0.088 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
5 1.7927905 0.197 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
6 1.7930637 0.095 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'
7 1.7934738 0.050 'Co K\a' 'G. Hölzer et al. Phys. Rev. A 56, 4554'

_pd_instr.id 58b6d83b
_pd_instr.geometry Bragg-Brentano
_pd_instr.cons_illum_len 12.0
_pd_instr.detector_circle_radius 117.5
_pd_instr.dist_src_spec 117.5
_pd_instr.beam_size_ax 9.8
_pd_instr.slit_ax_src_spec 9.5
_pd_instr.soller_ax_src_spec 5.0
_pd_instr.source_size_ax 8.5
_pd_instr.source_size_eq 0.4
_pd_instr.location
'ACME Measurements, 123 Main St. Maintown.'
;
;
This instrument is identified by the id 58b6d83b. The instrument is
described as a Bragg-Brentano diffractometer. The instrument is run
with a constant illumination length of 12 mm.

The distance from the source to the specimen for all measurement points
is 117.5 mm, which is identical to the distance from the source to the
specimen, as the X-ray tube is mounted on the detector circle. The width
of the beam on the specimen, in the axial direction, is 9.8 mm, and the
width of the beam is defined at the source by a 9.5 mm mask.

There are 5.0° axial Soller slits between the source and the specimen.
The size of the source in the X-ray tube is 8.5 x 0.4 mm.

The instrument is located at ACME Measurements in Maintown.

The radiation used in the instrument is defined by data names from the
DIFFRN_RADIATION_WAVELENGTH category. In this case, it is Co K\a
radiation as described by the constituent seven wavelengths, as
described by G. Hölzer et al. Phys. Rev. A 56, 4554.
;

save_

save_pd_instr.2theta_monochr_pre
Expand Down Expand Up @@ -13659,8 +13771,9 @@ save_
disparate loop; they cannot be assigned values independently.

Added examples to PD_CALC_OVERALL, PD_CALIB_INCIDENT_INTENSITY, PD_CHAR,
PD_DIFFRACTOGRAM, PD_MEAS_OVERALL, PD_PEAK, _pd_phase.id, PD_PHASE_MASSS,
PD_PREP, PD_PROC_LS, PD_QPA_CALIB_FACTOR, PD_QPA_INTERNAL_STD, PD_SPEC.
PD_DIFFRACTOGRAM, PD_INSTR, PD_MEAS_OVERALL, PD_PEAK, _pd_phase.id,
PD_PHASE_MASSS, PD_PREP, PD_PROC_LS, PD_QPA_CALIB_FACTOR,
PD_QPA_INTERNAL_STD, PD_SPEC.

Add _pd_peak.overall_id.