🧪 Test Results DashboardSummary
❌ Significant Test Failures🔍 Failed Tests (391 failures)Linux-c++ (391 failures)ModelFixture.Issue_4372.ModelFixture.Issue_4372 (run1)Error Message: Full Details: ModelFixture.Issue_4837.ModelFixture.Issue_4837 (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2.ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2 (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run1)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2.GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2 (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ASHRAECourthouse.GltfFixture.GltfForwardTranslator_ASHRAECourthouse (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest.GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_15023_Model12.GltfFixture.GltfForwardTranslator_15023_Model12 (run1)Error Message: Full Details: GltfFixture.GltfForwardTranslator_7_7_Windows_Complete.GltfFixture.GltfForwardTranslator_7_7_Windows_Complete (run1)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012.AirflowFixture.ForwardTranslator_DemoModel_2012 (run1)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories.AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories (run1)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2014.AirflowFixture.ForwardTranslator_DemoModel_2014 (run1)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012 (run1)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014 (run1)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames.OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames (run1)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default (run1)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded (run1)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault (run1)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor (run1)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor (run1)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor (run1)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor (run1)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation.OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC.OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource.OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp.OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump.OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump (run1)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces.OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary.OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating (run1)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow (run1)Error Message: Full Details: OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing.OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing (run1)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer.OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer (run1)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical (run1)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation.OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation (run1)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem.OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem (run1)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay.OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay (run1)Error Message: Full Details: OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed.OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial.OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone.OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged.OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged (run1)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc (run1)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed.OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed (run1)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc (run1)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc (run1)Error Message: Full Details: OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench.OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater.OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames.OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating.OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir.OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant.OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant (run1)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR (run1)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent.OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent (run1)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed.OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed (run1)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition.OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition (run1)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay.OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir.OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles.OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat.OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric.OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF.OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF (run1)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone.OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone (run1)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump.OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump (run1)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical (run1)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate (run1)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate (run1)Error Message: Full Details: OSVersionFixture.can_still_load_older_components.OSVersionFixture.can_still_load_older_components (run1)Error Message: Full Details: OSVersionFixture.update_3_10_0_to_3_10_1_People.OSVersionFixture.update_3_10_0_to_3_10_1_People (run1)Error Message: Full Details: OpenStudioCLI.Classic.run_compact_ruby_only_osw.OpenStudioCLI.Classic.run_compact_ruby_only_osw (run1)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.OpenStudioCLI.Classic.Run_RubyOnly (run1)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.OpenStudioCLI.Run_RubyOnly (run1)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.absolute_path.OpenStudioCLI.Classic.Run_RubyOnly.absolute_path (run1)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.absolute_path.OpenStudioCLI.Run_RubyOnly.absolute_path (run1)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly.OpenStudioCLI.Run_PythonOnly (run1)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly_TwoMeasure.OpenStudioCLI.Run_PythonOnly_TwoMeasure (run1)Error Message: Full Details: OpenStudioCLI.Run_RubyPython.OpenStudioCLI.Run_RubyPython (run1)Error Message: Full Details: OpenStudioCLI.Run_PythonRuby.OpenStudioCLI.Run_PythonRuby (run1)Error Message: Full Details: OpenStudioCLI.Run_AlfalfaWorkflow.OpenStudioCLI.Run_AlfalfaWorkflow (run1)Error Message: Full Details: OpenStudioCLI.Run_RubyPythonPlugin.OpenStudioCLI.Run_RubyPythonPlugin (run1)Error Message: Full Details: OpenStudioCLI.test_runner_errors.OpenStudioCLI.test_runner_errors (run1)Error Message: Full Details: OpenStudioCLI.test_outdated_measure.OpenStudioCLI.test_outdated_measure (run1)Error Message: Full Details: OpenStudioCLI.test_reporting_modeloutputrequests.OpenStudioCLI.test_reporting_modeloutputrequests (run1)Error Message: Full Details: OpenStudioCLI.test_bcl_measure_templates.OpenStudioCLI.test_bcl_measure_templates (run1)Error Message: Full Details: OpenStudioCLI.Classic.test_measure_manager.OpenStudioCLI.Classic.test_measure_manager (run1)Error Message: Full Details: CLITest-test_bundle-bundle.CLITest-test_bundle-bundle (run1)Error Message: Full Details: CLITest-test_bundle-bundle_git.CLITest-test_bundle-bundle_git (run1)Error Message: Full Details: CLITest-test_bundle-bundle_native_embedded.CLITest-test_bundle-bundle_native_embedded (run1)Error Message: Full Details: ModelFixture.Issue_4372.ModelFixture.Issue_4372 (run2)Error Message: Full Details: ModelFixture.Issue_4837.ModelFixture.Issue_4837 (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2.ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2 (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run2)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2.GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2 (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ASHRAECourthouse.GltfFixture.GltfForwardTranslator_ASHRAECourthouse (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest.GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_15023_Model12.GltfFixture.GltfForwardTranslator_15023_Model12 (run2)Error Message: Full Details: GltfFixture.GltfForwardTranslator_7_7_Windows_Complete.GltfFixture.GltfForwardTranslator_7_7_Windows_Complete (run2)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012.AirflowFixture.ForwardTranslator_DemoModel_2012 (run2)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories.AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories (run2)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2014.AirflowFixture.ForwardTranslator_DemoModel_2014 (run2)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012 (run2)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014 (run2)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames.OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames (run2)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default (run2)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded (run2)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault (run2)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor (run2)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor (run2)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor (run2)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor (run2)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation.OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC.OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource.OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp.OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump.OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump (run2)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces.OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary.OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating (run2)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow (run2)Error Message: Full Details: OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing.OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing (run2)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer.OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer (run2)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical (run2)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation.OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation (run2)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem.OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem (run2)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay.OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay (run2)Error Message: Full Details: OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed.OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial.OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone.OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged.OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged (run2)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc (run2)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed.OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed (run2)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc (run2)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc (run2)Error Message: Full Details: OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench.OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater.OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames.OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating.OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir.OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant.OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant (run2)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR (run2)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent.OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent (run2)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed.OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed (run2)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition.OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition (run2)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay.OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir.OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles.OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat.OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric.OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF.OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF (run2)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone.OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone (run2)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump.OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump (run2)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical (run2)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate (run2)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate (run2)Error Message: Full Details: OSVersionFixture.can_still_load_older_components.OSVersionFixture.can_still_load_older_components (run2)Error Message: Full Details: OSVersionFixture.update_3_10_0_to_3_10_1_People.OSVersionFixture.update_3_10_0_to_3_10_1_People (run2)Error Message: Full Details: OpenStudioCLI.Classic.run_compact_ruby_only_osw.OpenStudioCLI.Classic.run_compact_ruby_only_osw (run2)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.OpenStudioCLI.Classic.Run_RubyOnly (run2)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.OpenStudioCLI.Run_RubyOnly (run2)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.absolute_path.OpenStudioCLI.Classic.Run_RubyOnly.absolute_path (run2)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.absolute_path.OpenStudioCLI.Run_RubyOnly.absolute_path (run2)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly.OpenStudioCLI.Run_PythonOnly (run2)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly_TwoMeasure.OpenStudioCLI.Run_PythonOnly_TwoMeasure (run2)Error Message: Full Details: OpenStudioCLI.Run_RubyPython.OpenStudioCLI.Run_RubyPython (run2)Error Message: Full Details: OpenStudioCLI.Run_PythonRuby.OpenStudioCLI.Run_PythonRuby (run2)Error Message: Full Details: OpenStudioCLI.Run_AlfalfaWorkflow.OpenStudioCLI.Run_AlfalfaWorkflow (run2)Error Message: Full Details: OpenStudioCLI.Run_RubyPythonPlugin.OpenStudioCLI.Run_RubyPythonPlugin (run2)Error Message: Full Details: OpenStudioCLI.test_runner_errors.OpenStudioCLI.test_runner_errors (run2)Error Message: Full Details: OpenStudioCLI.test_outdated_measure.OpenStudioCLI.test_outdated_measure (run2)Error Message: Full Details: OpenStudioCLI.test_reporting_modeloutputrequests.OpenStudioCLI.test_reporting_modeloutputrequests (run2)Error Message: Full Details: OpenStudioCLI.test_bcl_measure_templates.OpenStudioCLI.test_bcl_measure_templates (run2)Error Message: Full Details: CLITest-test_bundle-bundle.CLITest-test_bundle-bundle (run2)Error Message: Full Details: CLITest-test_bundle-bundle_git.CLITest-test_bundle-bundle_git (run2)Error Message: Full Details: CLITest-test_bundle-bundle_native_embedded.CLITest-test_bundle-bundle_native_embedded (run2)Error Message: Full Details: ModelFixture.Issue_4372.ModelFixture.Issue_4372 (run3)Error Message: Full Details: ModelFixture.Issue_4837.ModelFixture.Issue_4837 (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2.ModelFixture.ThreeJSForwardTranslator_ParkUnder_Retail_Office_C2 (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_7_7_Windows_Complete_GeometryDiagnostics (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics.ModelFixture.ThreeJSForwardTranslator_RefBldgOutPatientNew2004_Chicago_GeometryDiagnostics (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run3)Error Message: Full Details: ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.ModelFixture.ThreeJSForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2.GltfFixture.GltfForwardTranslator_ParkUnder_Retail_Office_C2 (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_ASHRAECourthouse.GltfFixture.GltfForwardTranslator_ASHRAECourthouse (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSecondarySchoolNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgHospitalNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgOutPatientNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgSmallHotelNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgFullServiceRestaurantNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeHotelNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago.GltfFixture.GltfForwardTranslator_RefBldgLargeOfficeNew2004_Chicago (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest.GltfFixture.GltfForwardTranslator_Space_SurfaceMatch_LargeTest (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_15023_Model12.GltfFixture.GltfForwardTranslator_15023_Model12 (run3)Error Message: Full Details: GltfFixture.GltfForwardTranslator_7_7_Windows_Complete.GltfFixture.GltfForwardTranslator_7_7_Windows_Complete (run3)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012.AirflowFixture.ForwardTranslator_DemoModel_2012 (run3)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories.AirflowFixture.ForwardTranslator_DemoModel_2012_BadStories (run3)Error Message: Full Details: AirflowFixture.ForwardTranslator_DemoModel_2014.AirflowFixture.ForwardTranslator_DemoModel_2014 (run3)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2012 (run3)Error Message: Full Details: AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014.AirflowFixture.SurfaceNetworkBuilder_DemoModel_2014 (run3)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames.OSVersionFixture.update_2_9_1_to_3_0_0_fuelTypeRenames (run3)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default (run3)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_default_expanded (run3)Error Message: Full Details: OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault.OSVersionFixture.update_2_9_1_to_3_0_0_ShadowCaculation_nondefault (run3)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXSingleSpeed_minOATCompressor (run3)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoStageWithHumidityControlMode_minOATCompressor (run3)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXMultiSpeed_minOATCompressor (run3)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXVariableSpeed_minOATCompressor (run3)Error Message: Full Details: OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor.OSVersionFixture.update_3_0_0_to_3_0_1_CoilCoolingDXTwoSpeed_minOATCompressor (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation.OSVersionFixture.update_3_0_1_to_3_1_0_AvailabilityManagerHybridVentilation (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC.OSVersionFixture.update_3_0_1_to_3_1_0_AirLoopHVAC (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms.OSVersionFixture.update_3_0_1_to_3_1_0_fuelTypesRenames_MeterCustoms (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource.OSVersionFixture.update_3_0_1_to_3_1_0_ConstructionWithInternalSource (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp.OSVersionFixture.update_3_0_1_to_3_1_0_ZoneHVACLowTemp (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump.OSVersionFixture.update_3_0_1_to_3_1_0_WaterHeaterHeatPump (run3)Error Message: Full Details: OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces.OSVersionFixture.update_3_0_1_to_3_1_0_ShadingControl_and_SubSurfaces (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACLowTempRadiantVarFlow_Coils (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneAirMassFlowConservation (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary.OSVersionFixture.update_3_1_0_to_3_2_0_ConstructionAirBoundary (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilCoolingWaterToAirHeatPumpEquationFit (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_1_0_to_3_2_0_CoilHeatingWaterToAirHeatPumpEquationFit (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitCooling (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating.OSVersionFixture.update_3_1_0_to_3_2_0_HeatPumpWaterToWaterEquationFitHeating (run3)Error Message: Full Details: OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow.OSVersionFixture.update_3_1_0_to_3_2_0_ZoneHVACTerminalUnitVariableRefrigerantFlow (run3)Error Message: Full Details: OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing.OSVersionFixture.update_3_2_0_to_3_2_1_WaterHeaterSizing (run3)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer.OSVersionFixture.update_3_2_1_to_3_3_0_AirTerminalSingleDuctInletSideMixer (run3)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_2_1_to_3_3_0_GroundHeatExchangerVertical (run3)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation.OSVersionFixture.update_3_2_1_to_3_3_0_ControllerMechanicalVentilation (run3)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem.OSVersionFixture.update_3_2_1_to_3_3_0_SizingSystem (run3)Error Message: Full Details: OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay.OSVersionFixture.update_3_2_1_to_3_3_0_DesignDay (run3)Error Message: Full Details: OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed.OSVersionFixture.update_3_3_0_to_3_4_0_CoilHeatingDXMultiSpeed (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial.OSVersionFixture.update_3_4_0_to_3_5_0_AirWallMaterial (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_twoDims (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXSingleSpeed (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXSingleSpeed (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingDXMultiSpeedStageData (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXMultiSpeedStageData (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingDXCurveFitSpeed (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingWaterToAirHeatPumpEquationFit (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit.OSVersionFixture.update_3_4_0_to_3_5_0_CoilCoolingWaterToAirHeatPumpEquationFit (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone.OSVersionFixture.update_3_4_0_to_3_5_0_SizingZone (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage.OSVersionFixture.update_3_4_0_to_3_5_0_CoilHeatingGasMultiStage (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged.OSVersionFixture.update_3_4_0_to_3_5_0_ZoneHVACPackaged (run3)Error Message: Full Details: OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc.OSVersionFixture.update_3_4_0_to_3_5_0_TableMultiVariableLookup_oneDim_osc (run3)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed.OSVersionFixture.update_3_5_0_to_3_5_1_UnitarySystemPerformanceMultispeed (run3)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v350_osc (run3)Error Message: Full Details: OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc.OSVersionFixture.update_3_5_0_to_3_5_1_VRF_Terminal_v340_osc (run3)Error Message: Full Details: OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench.OSVersionFixture.update_3_5_1_to_3_6_0_GroundHeatExchangerHorizontalTrench (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_6_1_to_3_7_0_GroundHeatExchangerVertical (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_default (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_CorrectCombos (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos.OSVersionFixture.update_3_6_1_to_3_7_0_UnitarySystem_SAFMethods_IncorrectCombos (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_RatedFanPowerPerVolumeFlowRate (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_CrankcaseCurve (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_solo (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_eqfit (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_unitary_vsdeqfit (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp.OSVersionFixture.update_3_6_1_to_3_7_0_Coils_Latent_wahp (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater.OSVersionFixture.update_3_6_1_to_3_7_0_BoilerHotWater (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames.OSVersionFixture.update_3_6_1_to_3_7_0_fuelTypeRenames (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating.OSVersionFixture.update_3_6_1_to_3_7_0_CoilsHeating (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictHeating (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch.OSVersionFixture.update_3_6_1_to_3_7_0_DistrictObjects_CapacityFracSch (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir.OSVersionFixture.update_3_6_1_to_3_7_0_ControllerOutdoorAir (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant.OSVersionFixture.update_3_6_1_to_3_7_0_LoadProfilePlant (run3)Error Message: Full Details: OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_6_1_to_3_7_0_HeatPumpPlantLoopEIR (run3)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent.OSVersionFixture.update_3_7_0_to_3_8_0_HeatExchangerAirToAirSensibleAndLatent (run3)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed.OSVersionFixture.update_3_7_0_to_3_8_0_NoLoadSupplyAirFlowRateControlSetToLowSpeed (run3)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition.OSVersionFixture.update_3_7_0_to_3_8_0_PeopleDefinition (run3)Error Message: Full Details: OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay.OSVersionFixture.update_3_7_0_to_3_8_0_ScheduleDay (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir.OSVersionFixture.update_3_8_0_to_3_9_0_ControllerOutdoorAir (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles.OSVersionFixture.update_3_8_0_to_3_9_0_OutputControlFiles (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR.OSVersionFixture.update_3_8_0_to_3_9_0_HeatPumpPlantLoopEIR (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat.OSVersionFixture.update_3_8_0_to_3_9_0_AirTerminalSingleDuctPIUReheat (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric.OSVersionFixture.update_3_8_0_to_3_9_0_ChillerElectric (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF.OSVersionFixture.update_3_8_0_to_3_9_0_ZoneHVACTerminalUnitVRF (run3)Error Message: Full Details: OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone.OSVersionFixture.update_3_8_0_to_3_9_0_SizingZone (run3)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump.OSVersionFixture.update_3_9_0_to_3_10_0_WaterHeaterHeatPump (run3)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical.OSVersionFixture.update_3_9_0_to_3_10_0_GroundHeatExchangerVertical (run3)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_ZoneVentilationDesignFlowRate (run3)Error Message: Full Details: OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate.OSVersionFixture.update_3_9_0_to_3_10_0_SpaceInfiltrationDesignFlowRate (run3)Error Message: Full Details: OSVersionFixture.can_still_load_older_components.OSVersionFixture.can_still_load_older_components (run3)Error Message: Full Details: OSVersionFixture.update_3_10_0_to_3_10_1_People.OSVersionFixture.update_3_10_0_to_3_10_1_People (run3)Error Message: Full Details: OpenStudioCLI.Classic.run_compact_ruby_only_osw.OpenStudioCLI.Classic.run_compact_ruby_only_osw (run3)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.OpenStudioCLI.Classic.Run_RubyOnly (run3)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.OpenStudioCLI.Run_RubyOnly (run3)Error Message: Full Details: OpenStudioCLI.Classic.Run_RubyOnly.absolute_path.OpenStudioCLI.Classic.Run_RubyOnly.absolute_path (run3)Error Message: Full Details: OpenStudioCLI.Run_RubyOnly.absolute_path.OpenStudioCLI.Run_RubyOnly.absolute_path (run3)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly.OpenStudioCLI.Run_PythonOnly (run3)Error Message: Full Details: OpenStudioCLI.Run_PythonOnly_TwoMeasure.OpenStudioCLI.Run_PythonOnly_TwoMeasure (run3)Error Message: Full Details: OpenStudioCLI.Run_RubyPython.OpenStudioCLI.Run_RubyPython (run3)Error Message: Full Details: OpenStudioCLI.Run_PythonRuby.OpenStudioCLI.Run_PythonRuby (run3)Error Message: Full Details: OpenStudioCLI.Run_AlfalfaWorkflow.OpenStudioCLI.Run_AlfalfaWorkflow (run3)Error Message: Full Details: OpenStudioCLI.Run_RubyPythonPlugin.OpenStudioCLI.Run_RubyPythonPlugin (run3)Error Message: Full Details: OpenStudioCLI.test_runner_errors.OpenStudioCLI.test_runner_errors (run3)Error Message: Full Details: OpenStudioCLI.test_outdated_measure.OpenStudioCLI.test_outdated_measure (run3)Error Message: Full Details: OpenStudioCLI.test_reporting_modeloutputrequests.OpenStudioCLI.test_reporting_modeloutputrequests (run3)Error Message: Full Details: OpenStudioCLI.test_bcl_measure_templates.OpenStudioCLI.test_bcl_measure_templates (run3)Error Message: Full Details: CLITest-test_bundle-bundle.CLITest-test_bundle-bundle (run3)Error Message: Full Details: CLITest-test_bundle-bundle_git.CLITest-test_bundle-bundle_git (run3)Error Message: Full Details: CLITest-test_bundle-bundle_native_embedded.CLITest-test_bundle-bundle_native_embedded (run3)Error Message: Full Details: 📊 Test Run Information
|
| Test/DistrictCooling_GTest.cpp | ||
| Test/DistrictHeatingWater_GTest.cpp | ||
| Test/DistrictHeatingSteam_GTest.cpp |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Yikes - DistrictCooling and DistrictHeatingWater FT tests weren't being run...
ZoneHVAC:Baseboard:RadiantConvective:Steam and Pump:VariableSpeed:Condensate…r and CoilHeatingSteam.
| } else if (_heatingCoil->iddObject().type() == IddObjectType::Coil_Heating_Water) { | ||
| _heatingCoil->setString(Coil_Heating_WaterFields::AirInletNodeName, heatingCoilInletNodeName); | ||
| _heatingCoil->setString(Coil_Heating_WaterFields::AirOutletNodeName, heatingCoilOutletNodeName); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I'm confused here. The idd implies Coil:Heating:Water and Coil:Heating:Steam are valid for "Heating Coil Object Type", but "Heating Coil Name" doesn't list HeatingCoilName. Should it?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
E+ doesn't enforce IDD references nearly as much as we do.
I'm seeing that the Supplemental Heating Coil should support steam as least per E+ IDD, but indeed the Heating Coil field is confusing as you say.
E+ IDD:
AirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed,
[...]
A10, \field Heating Coil Object Type
\required-field
\type choice
\key Coil:Heating:DX:MultiSpeed
\key Coil:Heating:Electric:MultiStage
\key Coil:Heating:Gas:MultiStage
\key Coil:Heating:Water
\key Coil:Heating:Steam
\note Multi Speed DX, Electric, Gas, and Single speed Water and Steam coils
A11, \field Heating Coil Name
\required-field
\type object-list
\object-list HeatingCoilsDXMultiSpeed
\object-list HeatingCoilsElectricMultiStage
\object-list HeatingCoilsGasMultiStage
Seems like the C++ source code allows it. (don't mind the mention of "Supplemental" heating coil, this is a copy paste error, the supplemental heating coil is handled a few lines later around Line 1152 when it processes A14 and A15)
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
TL;DR: if you want to support it for that object, modify ProposedEnergy+.idd to add a reference.
- Either use HeatingCoilName, PROVIDED that it doesn't introduce new unsupported coils
- Add a new reference HeatingCoilSteamName to the Coil:Heating:Steam object and use that
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I don't think I can use HeatingCoilName because then it would introduce unsupported coils (e.g., Coil:Heating:Electric and Coil:Heating:Gas). Instead, I'll use the existing HeatingCoilsWater and add a new HeatingCoilsSteam reference.
| boost::optional<IdfObject> ForwardTranslator::createPipeAdiabatic(bool hasSteam) { | ||
| // PipeAdiabatic or PipeAdiabaticSteam | ||
|
|
||
| boost::optional<IdfObject> idfObject; | ||
| idfObject = IdfObject(IddObjectType::Pipe_Adiabatic); | ||
| if (hasSteam) { | ||
| idfObject = IdfObject(IddObjectType::Pipe_Adiabatic_Steam); | ||
| } else { | ||
| idfObject = IdfObject(IddObjectType::Pipe_Adiabatic); | ||
| } | ||
|
|
||
| return idfObject; | ||
| } |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
If hasSteam is true, then hasWater can't also be true because hasWaterAndSteam is run first (which checks for Water+Steam and throws).
| std::pair<bool, bool> ForwardTranslator::hasWaterAndSteam(Loop& loop) { | ||
| bool hasWater = false; | ||
| bool hasSteam = false; | ||
|
|
||
| std::vector<ModelObject> components = loop.components(); | ||
|
|
||
| for (auto& component : components) { | ||
| if (component.optionalCast<PipeAdiabatic>() || component.optionalCast<Node>() || component.optionalCast<Mixer>() | ||
| || component.optionalCast<Splitter>()) { // these are components associated with either Water or Steam | ||
| // no-op | ||
| } else if (component.optionalCast<BoilerSteam>() || component.optionalCast<DistrictHeatingSteam>() | ||
| || component.optionalCast<PumpVariableSpeedCondensate>() || component.optionalCast<CoilHeatingSteam>() | ||
| || component.optionalCast<CoilHeatingSteamBaseboardRadiant>()) { | ||
| hasSteam = true; | ||
| } else { | ||
| hasWater = true; | ||
| } | ||
| } | ||
|
|
||
| return std::pair<bool, bool>{hasWater, hasSteam}; | ||
| } | ||
|
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Check whether a given plant loop has both Water and Steam components. Instead of calling out every single Water component (there are many), assume Water if not Pipe/Node/Mixer/Splitter or Steam component. This method could probably be improved.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
My main problem with this is probably speed, due to the many optional Casts. Checking on iddObjectType is probably more efficient. Also, you know that some of these would be only on supply, others on demand.
The second thing is that I would rather have that method in the model namespace, for eg in PlantLoop.cpp, or perhaps even in Loop.cpp (might want to know if an AirLoopHVAC has steam or not)
| EXPECT_EQ(2u, ft.errors().size()); | ||
| EXPECT_EQ("Did not translate Object of type 'OS:PlantLoop' and named 'Plant Loop 1' because there is a mix of Water and Steam components.", | ||
| ft.errors().front().logMessage()); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I'm not totally sure why this error message gets thrown twice. I don't believe it's 1 for SupplyBranch and 1 for DemandBranch.
| // ZoneHVACTerminalUnitVariableRefrigerantFlow | ||
|
|
||
| std::vector<ZoneHVACTerminalUnitVariableRefrigerantFlow> zoneHVACTerminalUnitVariableRefrigerantFlow; | ||
|
|
||
| zoneHVACTerminalUnitVariableRefrigerantFlow = this->model().getConcreteModelObjects<ZoneHVACTerminalUnitVariableRefrigerantFlow>(); | ||
|
|
||
| for (const auto& elem : zoneHVACTerminalUnitVariableRefrigerantFlow) { | ||
| if (boost::optional<HVACComponent> coil = elem.supplementalHeatingCoil()) { | ||
| if (coil->handle() == this->handle()) { | ||
| return elem; | ||
| } | ||
| } | ||
| } |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Looks like ZoneHVACTerminalUnitVariableRefrigerantFlow accepts both Coil:Heating:Water and Coil:Heating:Steam as supplemental heating coil.
|
CI Results for 2197a10:
|
Pull request overview
Coil:Heating:Steam(this enables use of already-wrappedBoiler:SteamandDistrictHeating:Steam)Pump:VariableSpeed:Condensate#5070ZoneHVAC:Baseboard:RadiantConvective:Steam#5071CoilHeatingSteam is a WaterToAirComponent.
ZoneHVACBaseboardRadiantConvectiveSteam is a ZoneHVACComponent.
CoilHeatingSteamBaseboardRadiant is a StraightComponent.
PumpVariableSpeedCondensate is a StraightComponent.
TODO:
Pull Request Author
src/model/test)src/energyplus/Test)src/osversion/VersionTranslator.cpp)Labels:
IDDChangeAPIChangePull Request - Ready for CIso that CI builds your PRReview Checklist
This will not be exhaustively relevant to every PR.